Close

VESDA LCD Programmer & High Level Interfaces

VHH-100 Hand Held Programmer & Cable

P-VESDA-PROG

The VESDA LCD Programmer is menu driven, allowing the user to conveniently configure, commission and maintain a VESDA aspirating smoke detection system, as well as program each individual detector. Only one programmer is needed to support the entire network. This hand-held version simply plugs into a VESDAnet socket located on a detector or in a remote area. It is designed specifically for convenient onsite maintenance and service diagnostics.

The programmer module is a hand-held device (with included DB15 serial cable) and can be mounted into a VESDA VLP or VESDA VLS detector, a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called “Soft Keys” and are assigned programming options appropriate to the screen being viewed.

Some of the parameters that can be accessed via the programmer include device status reporting, zone number and name allocation, flow normalisation, alarm threshold setting (day, night, weekend), initiation of AutoLearn, wiring order, relay testing and event log review.

The VESDA LCD Programmer is menu driven, allowing the user to conveniently configure, commission and maintain a VESDA aspirating smoke detection system, as well as program each individual detector. Only one programmer is needed to support the entire network. This hand-held version simply plugs into a VESDAnet socket located on a detector or in a remote area. It is designed specifically for convenient onsite maintenance and service diagnostics.

The programmer module is a hand-held device (with included DB15 serial cable) and can be mounted into a VESDA VLP or VESDA VLS detector, a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called “Soft Keys” and are assigned programming options appropriate to the screen being viewed.

Some of the parameters that can be accessed via the programmer include device status reporting, zone number and name allocation, flow normalisation, alarm threshold setting (day, night, weekend), initiation of AutoLearn, wiring order, relay testing and event log review.

  • Send to a friend

    Send to a friend

    VHH-100 Hand Held Programmer & Cable

    VHH-100 Hand Held Programmer & Cable

    The VESDA LCD Programmer is menu driven, allowing the user to conveniently configure, commission and maintain a VESDA aspirating smoke detection system, as well as program each individual detector. Only one programmer is needed to support the entire network. This hand-held version simply plugs into a VESDAnet socket located on a detector or in a remote area. It is designed specifically for convenient onsite maintenance and service diagnostics.

    The programmer module is a hand-held device (with included DB15 serial cable) and can be mounted into a VESDA VLP or VESDA VLS detector, a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called “Soft Keys” and are assigned programming options appropriate to the screen being viewed.

    Some of the parameters that can be accessed via the programmer include device status reporting, zone number and name allocation, flow normalisation, alarm threshold setting (day, night, weekend), initiation of AutoLearn, wiring order, relay testing and event log review.

    Recipient :

    * Required fields

      or  Cancel

  • Product Information

    The VESDA LCD Programmer is menu driven, allowing the user to conveniently configure, commission and maintain a VESDA aspirating smoke detection system, as well as program each individual detector. Only one programmer is needed to support the entire network. This hand-held version simply plugs into a VESDAnet socket located on a detector or in a remote area. It is designed specifically for convenient onsite maintenance and service diagnostics.

    Features

    • User friendly menu system
    • Supports multiple languages
    • Single point access to entire VESDAnet system
    • Alarm and fault simulation
    • Shows wiring order
    • Locates communications failures
    • Password security
    • Hand held or remote mounting
    • Automatic Logoff when inactive
    • Backlit LCD screen

    The programmer module is a hand-held device (with included DB15 serial cable) and can be mounted into a VESDA VLP or VESDA VLS detector, a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called “Soft Keys” and are assigned programming options appropriate to the screen being viewed. Some of the parameters that can be accessed via the programmer include device status reporting, zone number and name allocation, flow normalisation, alarm threshold setting (day, night, weekend), initiation of AutoLearn, wiring order, relay testing and event log review.

    Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number (PIN), and one Distributor, can log onto a VESDAnet system under one of three levels of access which are password protected:

    • User (USR) is only able to view parameters, check status, alarms and reset the system
    • Administrator (ADM ) has access to most commands and programming parameters
    • Distributor (DST) is the topmost level and has unlimited access to all commands and parameters in the system
    • Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer


    The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.

    8 other products in the same category