P-VEU-A10
This product is no longer in stock
Availability date:
VESDA-E VEU-A10 with 3.5" Display
Recipient :
* Required fields
or Cancel
Flair is the revolutionary new detection chamber that forms the core of VESDA-E VEU, providing better detection, fewer nuisance alarms, higher stability, increased longevity and particle characterisation. Direct imaging of the sampled particles using a CMOS imager combined with multiple photo-diodes provides vastly more data that can be used to derive actionable information about the observed particles using analytics.
VESDA-E VEU features a robust IP40-rated enclosure and is equipped with a powerful aspirator that provides a total pipe length of 800 m (2,624 ft). Out of box operation is made possible with AutoConfig which allows airflow normalisation and AutoLearn Smoke and Flow to be initiated from within the detector. VEU is fully supported by the ASPIRE and Xtralis VSC software applications which facilitate ease of pipe network design, system commissioning and maintenance.
VESDA devices communicate on VESDAnet which provides a robust bi-directional communication network allowing continued redundant operation even during single point wiring failures. VESDAnet enables primary reporting, centralized configuration, control, maintenance and monitoring.
VESDA-E detectors offer Ethernet and WiFi connectivity as standard features. The detector can be added to a corporate network, allowing WiFi enabled tablet devices and laptops installed with Xtralis configuration software to connect wirelessly to the detector via the network.
VESDA-E VEU is fully compatible with existing VESDA installations. The detector occupies the same mounting footprint, pipe, conduit and electrical connector positioning as VESDA VLP. VEU is also compatible with existing VESDAnet installations allowing monitoring of both VESDA-E and legacy detectors via the latest iVESDA application.
The VEU series of aspirating smoke detectors are the premium detector of the new VESDA-E range. An Ultra-wide sensitivity range; 15 times greater than VESDA VLP, and provision for more sampling holes provide an increased coverage in high airflow applications by up to 40%. Considerably longer linear pipe runs and extended branched pipe network configurations cater perfectly to applications with higher ceilings providing an increased coverage by up to 80% whilst allowing convenient detector mounting for ease of service and maintenance. A range of revolutionary new features provide unsurpassed detection performance, flexibility, field programmability, connectivity and reduced total cost of ownership.
• Accommodation | • Hospitals & Healthcare | • Insurance |
• Correctional Facilities | • Clean Rooms | • Cold Storage |
• Cultural/Heritage | • Data & Telecom | • Education |
• Transportation | • Wind Power Generation | • Warehousing |
• Marine | • Nuclear Facilities | • Offices |
• Portable Switch Rooms | • Oil & Gas | • Power Generation |
• Records Storage | • Retail | And More... |
Supply Voltage | 18-30VDC (24V Nominal) | |||||
Power Consumption @ 24 VDC | P-VEU-A00 | P-VEU-A10 | ||||
Aspirator Setting | 1 | 5 | 10 | 1 | 5 | 10 |
Power (Quiescent) | 7.0W | 8.8W | 14.7W | 8.2W | 10.0W | 15.8W |
Power (In Alarm) | 7.8W | 9.6W | 15.5W | 10.4W | 11.6W | 16.6W |
Dimensions (WHD): | 350mm x 225mm x 135mm | |||||
Weight | P-VEU-A00: 4.83kg | |||||
P-VEU-A10: 4.9kg | ||||||
Operating Conditions | Ambient: 0°C to 39°C | |||||
Sampled Air: -20°C to 60°C | ||||||
Tested to: -20°C to 55°C | ||||||
UL: -20°C to 50°C | ||||||
Humidity: 10% to 95% RH, Non-condensing | ||||||
Area Coverage (max) | 6,500m2 | |||||
Min. Airflow Per Pipe | 15 l/m | |||||
Pipe Lengths Depending on Number of Pipes in Use | 1 Pipe | 2 Pipes | 3 Pipes | 4 Pipes | ||
160m | 150m | 130m | 100m | |||
Pipe Lengths (max) | Total pipe length (with branches): 800m | |||||
Analytics | DieselTrace™, DustTrace™, WireTrace™ | |||||
No. of holes (A/B/C) | 80/80/100 | |||||
Computer design tool | ASPIRE | |||||
Relays | 7 programmable relays (latching or non-latching states) | |||||
Contacts rated 2 A @ 30 VDC (Resistive) | ||||||
Dynamic Range | 0.0002%/m to 20% obs/m | |||||
Sensitivity Range | 0.001% - 20.0% obs/m | |||||
Software features | Event log: Up to 20,000 events |