Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK490 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems, where the appearance of a smooth wall is desired. The sprinkler orifice design, with a K-Factor of 5.8 (83.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The operating element and special deflector characteristics meet the challenges of residential sprinkler standards.  The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush to the wall. The cover plate is available in several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. After the system has been tested and wall finish has been applied, the push-on design of the cover plate assembly allows easy installation of the cover plate with up to 1/4” (6.4 mm) adjustment. Sprinkler VK490 is provided with a pipe guide to properly locate the sprinkler and allow the 1/4” adjustment of the cover plate.

Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK490 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems, where the appearance of a smooth wall is desired. The sprinkler orifice design, with a K-Factor of 5.8 (83.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The operating element and special deflector characteristics meet the challenges of residential sprinkler standards.  The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush to the wall. The cover plate is available in several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. After the system has been tested and wall finish has been applied, the push-on design of the cover plate assembly allows easy installation of the cover plate with up to 1/4” (6.4 mm) adjustment. Sprinkler VK490 is provided with a pipe guide to properly locate the sprinkler and allow the 1/4” adjustment of the cover plate.

  • Send to a friend

    Send to a friend

    VK490 - Residential Concealed Horizontal Sidewall Sprinkler (K5.8)

    VK490 - Residential Concealed Horizontal Sidewall Sprinkler (K5.8)

    Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK490 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems, where the appearance of a smooth wall is desired. The sprinkler orifice design, with a K-Factor of 5.8 (83.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The operating element and special deflector characteristics meet the challenges of residential sprinkler standards.  The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush to the wall. The cover plate is available in several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. After the system has been tested and wall finish has been applied, the push-on design of the cover plate assembly allows easy installation of the cover plate with up to 1/4” (6.4 mm) adjustment. Sprinkler VK490 is provided with a pipe guide to properly locate the sprinkler and allow the 1/4” adjustment of the cover plate.

    Recipient :

    * Required fields

      or  Cancel

  • 

    Downloads

    TECHNICAL DATA SHEETS
    BROCHURE
    CERTIFICATE
    GUIDE
    REVIT FILES

    Features

    • K Factor: 5.8 (USA) / 8.4 (NZ)
    • Maximum Spacing: 4.9 x 5.5m
    • Maximum Working Pressure: 175 psi (12 bar)
    • Minimum Spacing: 2.4m
    • Model Number: VK490
    • Occupancy Type: Residential
    • Response Type: Fast (Residential)
    • Thread Size: 1/2" NPT (15 mm BSP)

    Product Information

    Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK490 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems, where the appearance of a smooth wall is desired. The sprinkler orifice design, with a K-Factor of 5.8 (83.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The operating element and special deflector characteristics meet the challenges of residential sprinkler standards.  The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush to the wall. The cover plate is available in several decorative finishes to meet design requirements. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. After the system has been tested and wall finish has been applied, the push-on design of the cover plate assembly allows easy installation of the cover plate with up to 1/4” (6.4 mm) adjustment. Sprinkler VK490 is provided with a pipe guide to properly locate the sprinkler and allow the 1/4” adjustment of the cover plate.

    Coverage Area (ft / m)4-6" (102mm-152mm) From Ceiling6-12" (152mm-305mm) From Ceiling
    Flow (gpm / lpm)Pressure (psi / kPa)Flow (gpm / lpm)Pressure (psi / kPa)
    12 x 12 (3.7 x 3.7)16 (70)*7.6 (52)17 (64)**8.6 (59)
    14 x 14 (4.3 x 4.3)17 (64)*8.6 (59)17 (64)**8.6 (59)
    16 x 16 (4.9 x 4.9)18 (68)*9.6 (66)19 (72)**10.7 (74)
    16 x 18 (4.9 x 5.5)21 (80)*13.1 (90)21 (80)**13.1 (90)
    16 x 20 (4.9 x 6.1)23 (87)*15.7 (108) 26 (98)**20.1 (139)
    16 x 22 (4.9 x 6.7)31 (117)*28.6 (197)31 (117)** 28.6 (197)
    18 x 20 (5.5 x 6.1)28 (106)*23.3 (161)28 (106)**23.3 (161)
    *Centerline of the sprinkler located 4-3/8" (111mm) to 6-3/8" (162mm) below the ceiling.
    **Centerline of the sprinkler located 6-3/8" (162mm) to 12-3/8" (314mm) below the ceiling.