Close

Standard Coverage

There are 63 products.

Subcategories

  • Standard Response

    Standard Coverage Sprinkler Quick Reference Guide

    This guide is intended for general reference only. Prior to the design, layout, and/or installation of any sprinkler system, please refer to the technical documentation and always consult with the AHJ. FlameStop makes no representation or warranty as to whether following this guide will satisfy any rule or requirement. Please visit our downloads section for the most current technical data and product specifications. All products must be installed in accordance with the manufacturer's current installation instructions. FlameStop reserves the right to change product specifications at any time without notice and without incurring obligation.

    Suitable for Light, Ordinary, and Extra Hazard

    PendentUprightConventionalStainless Steel UprightStainless Steel Recessed Pendent
    5.6K
    VK1021 (p/n 19915) Temp Range 57-141°C
    VK1001 (p/n 19914) Temp Range 57-141°C
    VK118 (p/n 19383) Temp Range 68-182°C
    VK130 (p/n 05012B) Temp Range 68-260°C
    VK132 (p/n 06483B) Temp Range 68-260°C
    8.0K
    VK2021 (p/n 19923) Temp Range 57-141°C
    VK2001 (p/n 19922) Temp Range 57-141°C
    VK120 (p/n 18270) Temp Range 68-182°C
    VK368 (p/n 21928) Temp Range 71-96°C
    11.2K
    VK536 (p/n 07961) Temp Range 68-141°C
    VK530 (p/n 09679) Temp Range 68-141°C
    GB - Glass Bulb
    FL - Fusible Link
    ** - New XT1 Platform
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.

    Suitable for Light and Ordinary Hazard

    Flat Plate ConcealedFlush styleHigh Pressure PendentHigh Pressure UprightHigh Pressure Horizontal SidewallFlat Concealed Horizontal Sidewall
    5.6K
    VK492 (p/n 20034)
    VK400 (p/n 06697B)
    VK122 (p/n 09992)
    VK124 (p/n 09993)
    VK116 (p/n 09849)
    VK481 (p/n 17555)
    GB - Glass Bulb
    FL - Fusible Link
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.

    Suitable for Light Hazard only

    Horizontal SidewallVertical Sidewall
    5.6K
    VK104 (p/n 12995) Temp Range 57-182°C
    VK106 (p/n 12996) Temp Range 57-141°C
    GB - Glass Bulb
    - Also available in fusible link version
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.
  • Quick Response

    Standard Coverage Sprinkler Quick Reference Guide

    This guide is intended for general reference only. Prior to the design, layout, and/or installation of any sprinkler system, please refer to the technical documentation and always consult with the AHJ. FlameStop makes no representation or warranty as to whether following this guide will satisfy any rule or requirement. Please visit our downloads section for the most current technical data and product specifications. All products must be installed in accordance with the manufacturer's current installation instructions. FlameStop reserves the right to change product specifications at any time without notice and without incurring obligation.

    Suitable for Light and Ordinary Hazard

    PendentFlat Concealed PendentUprightHorizontal SidewallFlat Concealed Horizontal Sidewall
    5.6K
    VK3021 (p/n 19917) Temp Range 57-141°C
    VK462 (p/n 13503A) Temp Range 68-93°C
    VK3001 (p/n 19916) Temp Range 57-141°C
    VK305 (p/n 12997) Temp Range 57-141°C
    VK481 (p/n 17555) Temp Range 74-96°C
    8.0K
    VK3521 (p/n 19925) Temp Range 57-141°C
    VK464 (p/n 13614A) Temp Range 68-93°C
    VK3501 (p/n 19924) Temp Range 57-141°C
    VK360 (p/n 15591) Temp Range 57-93°C
    11.2K
    VK377 (p/n 08337) Temp Range 68-141°C
    VK531 (p/n 10633) Temp Range 68-141°C
    GB - Glass Bulb
    FL - Fusible Link
    ** - New XT1 Platform
    - Also available in fusible link version
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.

    Additional Quick Response Sprinklers

    ConventionalFlush PendentStainless Steel Upright/PendentMirage Concealed (MRI Room Sprinkler)
    5.6K
    VK310 (p/n 19391)
    VK402 (p/n 06702B)
    VK478 (p/n 19995)
    VK338 (p/n 14692)
    VK339 (p/n 14693)
    VK462-MRI (p/n 15480A)
    8.0K
    VK354 (p/n 18261)
    VK464-MRI (p/n 15481A)
    Mirage Concealed (high pressure)High Pressure PendentHigh Pressure UprightHigh Pressure Horizontal Sidewall
    5.6K
    VK463 (p/n 13667A)
    VK317 (p/n 12282)
    VK315 (p/n 12281)
    VK319 (p/n 12285)
    GB - Glass Bulb
    FL - Fusible Link
    - Also available in fusible link version
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.

    Suitable for Light Hazard Only

    PendentFlat Concealed PendentUprightHorizontal SidewallVertical Sidewall
    2.8K
    VK329 (p/n 12981) Temp Range 57-141°C
    VK461 (p/n 13831A) Temp Range 68-93°C
    VK325 (p/n 12980) Temp Range 57-141°C
    VK333 (p/n 10035) Temp Range 57-141°C
    4.2K
    VK331 (p/n 06720B) Temp Range 57-141°C
    VK465 (p/n 14262A) Temp Range 68-93°C
    VK327 (p/n 06719B) Temp Range 57-141°C
    5.6K
    VK3021 (p/n 19917) Temp Range 57-141°C
    VK462 (p/n 13503A) Temp Range 68-93°C
    VK3001 (p/n 19916) Temp Range 57-141°C
    VK305 (p/n 12997) Temp Range 57-141°C
    VK306 (p/n 12983) Temp Range 57-141°C
    GB - Glass Bulb
    ** - New XT1 Platform
    - Also available in fusible link version
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.

    Additional Quick Response Sprinklers

    High Pressure PendentHigh Pressure UprightHigh Pressure Horizontal Sidewall
    2.8K
    VK342 (p/n 12290)
    VK340 (p/n 12286)
    VK344 (p/n 12287)
    GB - Glass Bulb
    - Also available in fusible link version
    (NOTE) The above photos are for illustrative purposes only and might not exactly match the sprinkler indicated. Always refer to the technical documentation for product dimensions and physical characteristics.
per page
Showing 1 - 24 of 63 items
  • VK130

    

  • VK306

    

  • VK310

    

  • VK354

    

  • VK327

    

  • VK124

    

  • VK118

    

  • VK315

    

  • VK317

    

  • VK104

    

  • VK106

    

  • VK305

    

  • VK464

    

  • VK461

    

  • VK465

    

  • VK462

    

  • VK120

    

  • VK1021

    

  • VK1001

    

  • VK132

    

  • VK2021

    

  • VK2001

    

  • VK368

    

  • VK122

    

Showing 1 - 24 of 63 items
Close