Close

Gas Detection for VESDA

Gas Detection for VESDA There are no products in this category.

Subcategories

  • Sensepoint XCL Gas Detection for VESDA Pipe - Large Bore

    VESDA Sensepoint XCL – Large Bore

    VESDA Sensepoint XCL – Large Bore is designed to be easily incorporated to existing or new ASD pipe networks without major construction or electrical cabling / conduit and utilizes the flow in the pipe for the continuous delivery of air samples to the gas sensor for analysis. It is capable of remote sampling which means the detector can be placed outside the detection zone at a convenient location for maintenance and service where free business operation, restricted access and safety of personnel is important. Air drawn to the detector can be conditioned to remove contaminates which ensures the detector maintains reliable long-term performance in a wide range of environments. A single VESDA Sensepoint XCL – Large Bore detector delivers multi-point gas sampling capability giving it the advantage of providing larger coverage, increased design flexibility and reliable detection in high airflow areas compared to fixed point gas detectors.

    CLICK HERE FOR DATASHEET CLICK HERE FOR VIDEOS

    Part NumberProduct Name
    Large Bore
    P-XCL-LB-CH4-RAFlammable (CAT) 20-100% LEL - 4-20mA Analogue, Relay
    P-XCL-LB-O2-RAOxygen 25.0% v/v (Fixed) - 4-20mA Analogue, Relay
    P-XCL-LB-CO-RACarbon Monoxide 50 to 1000 ppm - 4-20mA Analogue, Relay
    P-XCL-LB-CO2PP-RACarbon Dioxide 1000 to 5000 ppm - 4-20mA Analogue, Relay
    P-XCL-LB-CO2VV-RACarbon Dioxide 1.0 to 5.0% v/v - 4-20mA Analogue, Relay
    P-XCL-LB-H2-RAHydrogen 1000ppm (Fixed) - 4-20mA Analogue, Relay
    P-XCL-LB-H2S-RAHydrogen Sulphide 10 to 50 ppm - 4-20mA Analogue, Relay
    P-XCL-LB-NO2-RANitrogen Dioxide 5 to 50 ppm - 4-20mA Analogue, Relay
    P-XCL-LB-NH3-RAAmmonia 50 to 200 ppm* - 4-20mA Analogue, Relay
    P-XCL-LB-CH4-RMFlammable (CAT) 20-100% LEL - Modbus RTU, Relay
    P-XCL-LB-O2-RMOxygen 25.0% v/v (Fixed) - Modbus RTU, Relay
    P-XCL-LB-CO-RMCarbon Monoxide 50 to 1000 ppm - Modbus RTU, Relay
    P-XCL-LB-CO2PP-RMCarbon Dioxide 1000 to 5000 ppm - Modbus RTU, Relay
    P-XCL-LB-CO2VV-RMCarbon Dioxide 1.0 to 5.0% v/v - Modbus RTU, Relay
    P-XCL-LB-H2-RMHydrogen 1000ppm (Fixed) - Modbus RTU, Relay
    P-XCL-LB-H2S-RMHydrogen Sulphide 10 to 50 ppm - Modbus RTU, Relay
    P-XCL-LB-NO2-RMNitrogen Dioxide 5 to 50 ppm - Modbus RTU, Relay
    P-XCL-LB-NH3-RMAmmonia 50 to 200 ppm* - Modbus RTU, Relay
    Spare Parts
    P-XCL-SC-CH4Flammable (CAT)
    P-XCL-SC-02Oxygen
    P-XCL-XRL-SC-COCarbon Monoxide
    P-XCL-SC-C02PPCarbon Dioxide (ppm)
    P-XCL-SC-C02VVCarbon Dioxide (% wv)
    P-XCL-XRL-SC-H2Hydrogen (ppm)
    P-XCL-SC-H2SHydrogen Sulphide (ppm)
    P-XCL-SC-N02Nitrogen Dioxide (ppm)
    P-XCL-SC-NH3Ammonia (ppm)*
    Spare Parts / Consumables
    P-XCL-LB-CAPFlow Cap
    P-XCL-LB-ELB60° Elbows – pack of 4
    P-XCL-M20-CGCable Glands – pack of 10
    P-XCL-LB-FLT-IFilter CAT, NH3, CO2 – pack of 10
    P-XCL-LB-FLT-2Filter CO, O2, H2S, NO2, H2 – pack of 10
    P-XCL-LB-COV-ISensor Cover CAT, NH3, CO2
    P-XCL-LB-COV-2Sensor Cover CO, O2, H2S, NO2, H2
  • Sensepoint XCL Gas Detection for VEA Detector

    Sensepoint XCL Gas Detection for VEA Detector

    When used with the VESDA-E VEA; VESDA Sensepoint XCL provides early warning of the presence of gases for occupant protection and system monitoring whilst at the same time ensuring protection against fire threats. Through its embedded Bluetooth interface, VESDA Sensepoint XCL enables customers to pair the gas detector with their smart device applications to perform installation, commissioning and maintenance. This ensures a faster VESDA Sensepoint XCL installation, rapid configuration, simplicity to operate, and simplified maintenance.

    CLICK HERE FOR DATASHEET CLICK HERE FOR VIDEOS

    Part NumberProduct Name
    Micro Bore
    P-XCL-VEA-CO-RAVESDA Sensepoint XCL CO 300ppm 4-20mA Relay for VEA
    P-XCL-VEA-CO-RMVESDA Sensepoint XCL CO 300ppm Modbus Relay for VEA
    P-XCL-VEA-CH4-RAVESDA Sensepoint XCL CH4 0-100% LEL 4-20mA Relay for VEA
    P-XCL-VEA-CH4-RMVESDA Sensepoint XCL CH4 0-100% LEL Modbus Relay for VEA
    P-XCL-VEA-H2-RAVESDA Sensepoint XCL H2 1000ppm 4-20mA Relay for VEA
    P-XCL-VEA-H2-RMVESDA Sensepoint XCL H2 1000ppm Modbus Relay for VEA
    P-XCL-VEA-C02VV-RAVESDA Sensepoint XCL C02 5% v/v 4-20mA Relay for VEA
    P-XCL-VEA-C02VV-RMVESDA Sensepoint XCL C02 5% v/v Modbus Relay for VEA
    P-XCL-VEA-C02PP-RAVESDA Sensepoint XCL C02 5000ppm 4-20mA Relay for VEA
    P-XCL-VEA-C02PP-RMVESDA Sensepoint XCL C02 5000ppm Modbus Relay for VEA
    P-XCL-VEA-CO-RA-55 x VESDA Sensepoint XCL CO 300ppm 4-20mA Relay for VEA
    P-XCL-VEA-CH4-RA-55 x VESDA Sensepoint XCL CH4 0-100% LEL 4-20mA Relay for VEA
    P-XCL-VEA-H2-RA-55 x VESDA Sensepoint XCL H2 1000ppm 4-20mA Relay for VEA
    Spare Parts
    P-XCL-FILTERVESDA Sensepoint XCL Replacement Filter - Pack of 10
    P-XCL-VEA-CALVESDA Sensepoint XCL Calibration/FIow cap for VEA
    P-XCL-M20-CGVESDA Sensepoint XCL Cable Glands - Pack of 10
    P-XCL-VEA-TUBVESDA Sensepoint XCL Tubing Interface for VEA
    P-XCL-COVERVESDA Sensepoint XCL Sensor Cover with Gasket
    P-XCL-XRL-SC-COVESDA Sensepoint XCL/XRL Replacement Sensor - CO 300ppm
    P-XCL-SC-CH4VESDA Sensepoint XCL Replacement Sensor - CH4 0-100% LEL
    P-XCL-XRL-SC-H2VESDA Sensepoint XCL/XRL Replacement Sensor - H2 1000ppm
    P-XCL-SC-C02VVVESDA Sensepoint XCL Replacement Sensor - C02 5% v/v
    P-XCL-SC-C02PPVESDA Sensepoint XCL Replacement Sensor - C02 5000ppm
  • VESDA ECO
    VESDA-ECO-Category-Header-.jpg

    These products have been replaced by Sensepoint XCL Gas Detection for VESDA Pipe - Large Bore

    Invisible hazards can originate from the release of toxic gases, oxygen deficiency, or the presence of combustible gases/vapors. As with fire detection, proactive gas detection enables countermeasures to be taken to protect personnel and property from such unseen dangers.
    VESDA ECO combines aspirating smoke detection with gas detection and environmental monitoring. It uses an existing VESDA pipe network to actively sample air for the presence of smoke as well as hazardous/combustible gases. Integration with other building systems (FACP, PLC, HVAC and BMS) delivers real-time situational awareness and intelligent emergency response, including the activation of demand controlled ventilation to save energy and control costs.

    Features

    • Leverages existing VESDA pipe networks to cost effectively detect both smoke and gas in addition to providing environmental monitoring
    • Provides detection for multiple gases through simple expansion without major construction or retrofitting
    • Toxic, Oxygen or Flammable gas detection
    • Single or dual gas versions
    • Integral alarm status LED’s
    • Reduces energy consumption and costs through demand-controlled ventilation
    • Conditions air to remove dirt, particulates, moisture, poisonous agents, and cross-interference gases
    • Works in harsh environments
    • Provides non-intrusive detection for aesthetics or to prevent vandalism
    • Enables centralized monitoring and communication with building systems for real-time awareness
    • Integrates easily with FACP/PLC/HVAC/BMS

    Download Order Guide (521k)

Close