NC-FPS101

  • Sensitivity & calibration tester as required by AS1851 maintenance testing standard
  • The kit comes complete in carry bag and will fit onto any SOLO fibreglass poles
Operating parameters:
  • Maximum working height: 6.3m
  • Average test time: 120 seconds (1%/ft/minute fast ramp, 0.5%/ft/minute slow ramp)
  • Average calibration time:* 40 seconds
  • Average clearing time:* 120 seconds
  • Average tests per aerosol/canister 100 tests
  • Maximum obscuration for ionization: 4.00 %/ft
  • Maximum obscuration for photoelectric: 6.00 %/ft
  • Resolution: 0.01 %/ft
  • Average battery life: 8-10 hours testing on a full charge

Note: *can be conducted whilst walking between detectors

Type of aerosol:
  • Environmentally friendly, non-flammable, non toxic.
  • A Safety Data Sheet is available on request.
Calibration & servicing:
  • In operation: Self-calibrates before each test
  • Servicing intervals: 1 year recommended, but max interval 5000 tests
Environment:
  • Operating temperature: +10°C to +35°C
  • Storage temperature: -10°C to +50°C (Do not store in direct sunlight)
  • Humidity: 0-85% RH non-condensing
  • Weight of main unit (incl. aerosol canister): 3kg

Because our policy is one of continuous improvement, details described within this publication are subject to change without notice.

  • Sensitivity & calibration tester as required by AS1851 maintenance testing standard
  • The kit comes complete in carry bag and will fit onto any SOLO fibreglass poles
Operating parameters:
  • Maximum working height: 6.3m
  • Average test time: 120 seconds (1%/ft/minute fast ramp, 0.5%/ft/minute slow ramp)
  • Average calibration time:* 40 seconds
  • Average clearing time:* 120 seconds
  • Average tests per aerosol/canister 100 tests
  • Maximum obscuration for ionization: 4.00 %/ft
  • Maximum obscuration for photoelectric: 6.00 %/ft
  • Resolution: 0.01 %/ft
  • Average battery life: 8-10 hours testing on a full charge

Note: *can be conducted whilst walking between detectors

Type of aerosol:
  • Environmentally friendly, non-flammable, non toxic.
  • A Safety Data Sheet is available on request.
Calibration & servicing:
  • In operation: Self-calibrates before each test
  • Servicing intervals: 1 year recommended, but max interval 5000 tests
Environment:
  • Operating temperature: +10°C to +35°C
  • Storage temperature: -10°C to +50°C (Do not store in direct sunlight)
  • Humidity: 0-85% RH non-condensing
  • Weight of main unit (incl. aerosol canister): 3kg

Because our policy is one of continuous improvement, details described within this publication are subject to change without notice.

  • Send to a friend

    Send to a friend

    TruTest Smoke Detector Sensitivity Kit (Pole Not Included)

    TruTest Smoke Detector Sensitivity Kit (Pole Not Included)

    Recipient :

    * Required fields

      or  Cancel

  • Close